Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2007 Jan-Feb; 55(1): 43-7
Article in English | IMSEAR | ID: sea-70795

ABSTRACT

PURPOSE: To analyze the outcome of keratoplasty performed using Kalevar-Majumdar (K-M) media, a new synthetic viscous medium for preservation of the cornea. MATERIALS AND METHODS: The K-M media-preserved donor eye balls were kept in a bottle in a refrigerator at 4 degrees C till the corneas were used. Forty-eight consecutive keratoplasty cases of pseudophakic bullous keratopathy with vision less than counting fingers at one meter and operated by a single surgeon have been analyzed. Corneal donor button of 7.5 mm was used on the 7.0 mm recipient bed in all cases. Surgery was done with a standard technique. All the cases were examined daily for the first week and at the end of one month for graft clarity, epithelial defect and stromal edema. RESULTS: The K-M media-preserved corneal grafts remained clear at the end of the first week in 95.8% (46 of 48) cases and at the end of one month in 93.7% (45 of 48) cases. Donor epithelial haze cleared in 24 h in all cases. The stromal edema got cleared in the majority (91.7%, 44 of 48) within 24 h. Epithelial defect was seen in only 10.4% (five cases). There was no primary graft failure. CONCLUSION: K-M medium, a new viscous, synthetic corneal preservation medium, is a safe (no primary donor failure) alternative to conventional liquid corneal preservation media. K-M media-preserved eyes appear to have better preserved corneal epithelium with faster achievement of graft clarity postoperatively.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Cornea , Corneal Diseases/complications , Corneal Transplantation , Female , Humans , Male , Middle Aged , Organ Preservation Solutions/chemical synthesis , Pseudophakia/complications , Retrospective Studies , Treatment Outcome
2.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 554-6, 2007.
Article in English | WPRIM | ID: wpr-634986

ABSTRACT

In order to explore the method to prepare hypoxia UW solution and the stability and preservation of hypoxia UW solution, UW solution was purged by argon or air for 15 min or 60 at a flow rate of 0.8 or 2 L/min, and the oxygen partial pressure of UW solution was detected. The hypoxia UW solution was exposed to the air or sealed up to preserve by using different methods, and the changes of oxygen partial pressure was tested. The results showed that oxygen partial presure of 50 mL UW solution, purged by argon for 15 min at a flow rate of 2 L/min, was declined from 242+/-6 mmHg to 83+/-10 mmHg. After exposure to the air, oxygen partial pressure of hypoxia UW solution was gradually increased to 160+/-7 mmHg at 48 h. After sealed up by the centrifuge tube and plastic bad filled with argon, oxygen partial pressure of hypoxia UW solution was stable, about 88+/-13 mmHg at 72 h. It was concluded that oxygen of UW solution could be purged by argon efficiently. Sealed up by the centrifuge tube and plastic bag filled with argon, oxygen partial pressure of UW solution could be stabilized.


Subject(s)
Adenosine/chemical synthesis , Allopurinol/chemical synthesis , Hypoxia , Glutathione/chemical synthesis , Insulin/chemical synthesis , Organ Preservation/methods , Organ Preservation Solutions/chemical synthesis , Oxygen/analysis , Partial Pressure , Raffinose/chemical synthesis
SELECTION OF CITATIONS
SEARCH DETAIL